BMSの研究開発検証により、安全性と信頼性が保証されます。
CE-6'S-BMS-24S300A
Eliminate real battery testing risks with safe, efficient extreme condition simulation.
24-channel battery simulation replaces real battery packs (0-6V/±0.5mV accuracy), avoiding explosion risks from overcharge, over-discharge, and short-circuit tests. Precisely simulate SOC estimation, cell voltage/temperature variations, and evaluate BMS voltage monitoring accuracy.

High-Comprehensive BMS performance verification with 17 core test scenarios covered.
Balance strategy validation: Utilizing simulated battery packs to accurately mimic SOC differences among individual cells. This tests the BMS's balance control strategy, ensuring it can effectively minimize discrepancies between cells and prolong the battery pack's lifespan. Full-range control strategy testing : Including charge/discharge strategies, thermal management, and fault diagnosis (overvoltage/undervoltage/overtemperature, etc.), the system conducts comprehensive validation of:
- Relay control strategy
- SOC estimation
- Output power control
- Energy feedback
- Power-on/power-off sequences
- Charge management
- Thermal management strategies

Modular hardware design for flexible application.
- High-precision measurement capabilities for voltage (0-1500V), current (300A ±0.05%).
- 8-channel temperature simulation (NTC) with 2Ω-1MΩ adjustable resistance.
- Integrated insulation resistance testing (50Ω-100MΩ range) and high voltage withstand capability up to 2000V.Integrated insulation resistance testing (50Ω-100MΩ range) and high voltage withstand capability up to 2000V.

Multi-protocol communication and customized adaptation.
- Multi-protocol communication testing: supports multiple protocols including CAN, RS485, IIC, SMBus, and Ethernet etc. The BMS test system is programmed according to the CAN communication protocols between BMS and ECU, motor controller, and charger. The PC software simulates devices that communicate with BMS.
- Customized compatibility: custom development of IO and devices based on customer requirements. Test steps can be freely programmed, and customized development is available for customer-specific BMS.

Smart data management and reporting.
Automated analysis: compare BMS readings (temp/current/voltage/resistance) against standards, calculating max/min/avg errors. Traceability: export to Excel, barcode (1D/2D) tracking.

| モデル | CE-6'S-BMS-24S300A |
| Current source module | |
| 電流源の範囲 | Range 1:50A; |
| Range 2:100A; | |
| Range 3:300A | |
| 正確さ | ±0.05% of F.S. |
| 解像度比 | 24bit |
| Simulated battery | |
| 単一セクションのバッテリー電圧出力範囲をシミュレートします。 | 0 ~ 6V |
| シミュレートされたバッテリーの電圧出力精度は単一セクションでシミュレートされます。 | 0.5mV |
| 単一セクションでシミュレートされたバッテリーの電圧を測定します | 0.5mV |
| チャンネル数 | 24CH |
| Temperature simulation | |
| 抵抗値の調整範囲 | 2Ω ~ 1MΩ |
| 調整可能な抵抗精度 | 0.2%RD+1.0Ω |
| 調整可能な抵抗分解能 | 1Ω |
| 調整可能な抵抗の数 | 8CH |
| Programmable high voltage constant pressure source | |
| 電圧範囲 | 0-1500V |
| 電流レンジ | 0 ~ 3.5A |
| 電圧精度 | 0.5%F.S. |
| 電流精度 | 0.5%F.S. |
| Insulation resistance simulator | |
| 抵抗値の範囲 | 50Ω ~ 100MΩ |
| 最大耐圧性 | 2000V |
| 解像度を調整する | 50Ω |